D-J-C
Minimum response time
generic-rs-485-port-minimum-response-time
Setting of this parameter avoids interference of communication at the RS-485 interface. For this pur-
pose the response to a command is delayed by the selected time. Additionally, the response is kept
compact.
Value range
Default
Units
0…2ˈ000
10
ms
D-J-D
Transmitter warm-up time
generic-rs-485-port-transmitter-warm-up-time
The transmitter warm-up time defines the time before data is sent.
Value range
Default
Units
0…2ˈ000
10
ms
D-J-E
Flow control
generic-rs-485-port-flow-control
The XOFF-XON flow control can be activated with this setting.
ID
Option
Description
1
Off (default)
no flow control
2
XOFF-XON blocking
XOFF-XON flow control, especially adapted for half-duplex systems
ATTENTION
To use spectrum mode (
) set
to
XOFF-XON blocking
. This enables a return to normal mode at any time.
D-J-F
Sending window
generic-rs-485-port-sending-window
If XON-XOFF flow control is activated data are transmitted in blocks with the defined length.
1
4
P
ar
am
et
er
d
ef
in
it
io
n
s
Manual
119