Function to adjust the measurement of the USH-9 temperature sensor. Applying this function will
update the setting
.
D-E-C
Test
generic-temperature-test
Function to test the USH-9 temperature sensor.
D-F IOUT settings
D-F-A
D-F-B
D-F-C
D-F-D
D-F-E
D-F-F
IOUT2, temperature 4-20 mA span
D-F-G
D-F-H
D-F-I
D-F-A
Status
generic-analog-out-status
The status defines the behavior of the analog outputs.
ID
Option
Description
1
off (default)
Analog outputs are inactive.
2
just during TRIG
Analog outputs are only active, if an external signal is
present at the TRIG input. The outputs are high as long as
the signal at the TRIG input is high.
3
always on
Analog outputs are permanently active.
D-F-B
IOUT1, function
ush-iout1-function
Defines the variable returned by IOUT1. The following options are available: