The figure below illustrates the default moving filter duration of 180 seconds. While a
of 90 seconds embraces two measurement values, an interval of 45 seconds includes 4 val-
ues.
Value range
Default
Units
0…99ˈ999ˈ999
180
s
C-G Moving filter, type
ush-moving-filter-type
The level/distance values in the buffer can be filtered by one of the following options:
ID
Option
Description
1
average
The mean value of all buffered values iss calculated.
2
elim. neg.
spikes
To eliminate negative spikes, the mean value is calculated without the
5 lowest buffered values. If the buffer size is smaller than 10, half of
the values are eliminated.
3
maximum
The highest value from the buffer is returned.
4
median
The median value of the buffered data is returned.
5
elim. pos.
spikes
To eliminate positive spikes, the mean value is calculated without the 5
highest buffered values. If the buffer size is smaller than 10, half of the
values are eliminated.
6
elim. all
spike
(default)
To eliminate positive and negative spikes, the mean value is calculated
without the 5 highest and 5 lowest buffered values. If the buffer size is
smaller than 15, two third of the values are eliminated.