EXAMPLE
#M0001G00se00
- 17.4|01
0.535|02
0.000|03
-
1.89|04 0.0|05 0|B11D;
This protocol is identical with the Sommer protocol except that the index of the measurement values
starts at 0 instead of 1.
This protocol has been implemented for compatibility reasons: When a Sommer device with firm-
ware < 2.0 is updated to version 2.x the protocol is automatically set to Sommer old. Thus, the setup
of a connected data logger does not have to be adjusted.
12.3.8 RS-485 commands
Command structure
The structure of serial commands and answers (
#W0001$mt|BE85;
) is described in the following
table:
Parameter
Format
Description
Start character
#
Identifier
X
W
USH-9 returns a confirmation on receipt. This
command type demands a closing sequence with a
valid CRC-16.
S
USH-9 does not acknowledge the receipt of the
command. This command type demands no closing
sequence and therefore no CRC-16.
R
USH-9 returns the requested measurement value
or parameter. This command type demands a closing
sequence with a valid CRC-16.
T
Write a volatile setting and receive a con-
firmation
A
Answer of device to read or write command
System key
dd
Device number
dd
Command
xxx
See
1
2
C
o
m
m
u
n
ic
at
io
n
Manual
71