ID
Option
Description
1
main values
Only the main values are returned.
2
& special values (default)
Main values and special values are returned.
3
& analysis values
Main, special and analysis values are returned.
11.6 Level/Distance measurements
11.6.1
The duration of a single measurement. During this time the ultrasonic signal is recorded and the dis-
tance to the monitored surface calculated. Generally, a measurement duration of 6 s is recom-
mended.
11.6.2
Function to test the level/distance measurement. Initiates a measurement and returns the current
distance and level.
11.6.3
Function to adjust the level measurement of the USH-9 to the actual level. It first initiates a meas-
urement and then requests the actual level.
11.6.4
The distance between the sensors lower edge and the ground surface, e.g. lowest point of river bed,
ground without snow.
11.6.5
Switch to activate the settings for specific applications as listed in the following table:
1
1
C
o
n
fi
gu
ra
ti
o
n
o
f
th
e
U
SH
-9
Manual
55