Function to adjust the level measurement of the USH-9 to the actual level. It first initiates a meas-
urement and then requests the actual level. Adjusting the level will alter the parameter
.
C-D Distance to zero level
ush-distance-zero-level
The distance between the sensors lower edge and the ground surface, e.g. lowest point of river bed,
ground without snow.
Value range
Default
Units
-9ˈ999ˈ999…99ˈ999ˈ999
10'000
mm
C-E Application
ush-application
Switch to activate the settings for specific applications as listed in the following table:
ID
Option
Description
1
snow
(default)
Settings for snow applications are active. These settings include precipitation
detection and snowfall limits (see
and
). Rate of
change filtering (
RoC, max. without precip. (./h)
and
)
is active.
2
water
Settings for water application are active. Precipitation detection and rate of
change filtering (RoC) are deactivated.
3
others
Settings for water and snow applications are inactive. Used for generic
level/distance measurements. A constant rate of change filter (
) is active.
C-F Moving filter, duration
ush-moving-filter-duration
Every level/distance measurement is stored internally in a buffer for filtering. This setting defines the
length of the time window of which the data are stored in the buffer. If the buffer is full, the oldest
value is replaced by the most recent one.