Device number
generic-rs-485-protocol-device-number
The device number is used for the unique identification of the device in a bus system.
Value range
Default
Units
0…98
0 (default)
-
D-I-B
System key
generic-rs-485-protocol-system-key
The system key defines the bus system of the device. Thus, different conceptual bus systems can be
separated. Interfering bus systems occur if the remote radio coverage of two measurement systems
overlap. In general, the system key should be set to 00.
Value range
Default
Units
0…99
0
-
D-I-C
Output protocol (OP)
generic-rs-485-protocol-output-protocol
The type of the serial output protocol. The following options are available:
ID
Option
Description
1
Sommer (default)
Sommer protocol; data values are returned with an index starting at 1
2
Standard
Standard protocol; data values are returned without an index
3
MODBUS
Modbus protocol
1
4
P
ar
am
et
er
d
ef
in
it
io
n
s