Snowfall is detected if
is exceeded and the tem-
perature is below
. To suppress this status set
to
≤0
.
A snow cover emerges if
is exceeded and
is not reached. To suppress this status set
to a negative value.
12.2.2 Special values
Index
Measurement
value
Unit
Description
05
Precipitation
-
Dimensionless value representing precipitation type and
intensity. Its range is 0 to 1000, where 1000 is the most
intensive precipitation that can be expected. The value
strongly depends on the type of precipitation: wet snow
that falls in large flakes gives high values, cold, small flakes
give lower values even though snowfall can be intense. Rain
generally gives lower values than snow.
The precipitation value is used to optimize the rate of
change filter (RoC) that is affected by reflections of pre-
cipitation. It cannot substitute a rain gauge.
06
Signal quality
dB
SNR (signal to noise ratio)
07
Std. deviation
mm
Standard deviation of the measured level
08
Supply voltage
V
Power supply voltage
Table 5
Special values
12.2.3 Analysis values
Index
Measurement value
Unit
Description
09
Signal focus
dB
Diagnostic variable
10
Signal strength
dB
Diagnostic variable
11
Half-value width
%
Diagnostic variable
1