Figure 11 - Examples of standard installations
Failure to comply with these requirements may prevent the correct operation of
the unit. Follow all the instructions presented on the diagrams.
The Hidro units operate with the combustion chamber in vacuum, so it is
absolutely necessary to have a fume exhaust pipe to extract combustion gases
properly.
Fume duct material:
The tubing must consist of 0,5 mm thick rigid stainless steel,
with fastening joints attaching the different sections and accessories.
Insulation:
The fume ducts must be double-walled and insulated to make sure that
fumes do not cool down going outwards, which would cause an inadequate circulation
and condensation that may damage the unit.
Output “T-tube”:
Always attach to the output of the unit a “T-tube” with a regulator.
Windproof terminal:
A windproof terminal must always be installed to avoid the
backflow of fumes.