102
Connection to central heating radiators with another boiler support and
sanitary water combined with solar panel
Figure 65 - Connection to central heating radiators with another boiler support and sanitary water combined with solar
panel
Note:
- The differential thermostat must have a hysterisis of 15 to 25 °C.
- Hydro independent “Off” (water temperature-controlled regulation), put the boiler
in “manual” mode and power level to “5”
- Modulating pump “On”
- Water sensing inhibition “On”
- Alternative hydro shutdown “On”
- Pump “On” = 50 °C
- Pump “Off” = same or thermostat temperature 1°C below the temperature
differential thermostat.
When using the generator with differential thermostat the machine must be connected
in the CONNECTION “Remote”.
Calculation deposits of inertia
: the boilers for pellets it’s recommended that the
buffer tank has 20l/kW.
NOTE:
For Columbus electronics when connecting the stove to the inertia tank it is
necessary to change the following parameters:
P77=04
A01=04
(Contact technical support if necessary)
1
1
1
Содержание Hidro 12
Страница 18: ...12 Figure 11 specifies the basic requirements for installing the chimney to the unit a b ...
Страница 102: ...96 ...
Страница 103: ...97 ...
Страница 104: ...98 ...
Страница 133: ...127 25 2 Flow chart Hidro 12 Flow chart 1 Lighting ...
Страница 134: ...128 ...
Страница 135: ...129 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...
Страница 136: ...130 25 3 Flow chart Hidro 17 and Hidro 23 Flow chart 1 Lighting ...
Страница 137: ...131 ...
Страница 138: ...132 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...