5
4.
Technical specifications
Features
Hidro 12
Hidro 17
Hidro 23
Un
Weight
185
202
219
kg
Height
1110
1192
1255
mm
Width
617
W
W
mm
Depth
707
710
767
mm
Diameter of the fume discharge pipe
80
100
100
mm
Reservoir capacity
30
36
55
kg
Maximum heating capacity
295
380
502
m³
Maximum overall thermal power (water/air)
11,5 / 1,5
14,5 / 2,2
18,8 / 3,3
kW
Minimum thermal power (water/air)
3,8 / 1,2
4,3 / 0,8
4,3 / 0,8
kW
Minimum fuel consumption
1,1
1,1
1,1
kg/h
Maximum fuel consumption
3,0
3,9
5,1
kg/h
Rated electric power
43
134
134
W
Electric power at start-up (<10 min.)
406
434
434
W
Rated voltage
230
230
230
V
Nominal frequency
50
50
50
Hz
Thermal yield at rated thermal power
92,0
90,9
89,2
%
Thermal yield at reduced thermal power
95,0
93,8
93,8
%
Combustion gas flow (max.)
21,0
6,9
6,9
g/s
Combustion gas flow (min.)
44,0
33,7
18,8
g/s
Max. gas temperature
108
126,5
153,4
ºC
Min. gas temperature
62
66
66
ºC
CO emissions at rated thermal power
0,0136
0,0162
0,0200
%
CO emissions at reduced thermal power
0,0256
0,0200
0,0200
%
Draught in the chimney
12
12
12
Pa
Unit water volume
19
22
22
L
Rated electric power
49,1
49,1
49,1
dB(A)
Table 1 - Technical specifications
Tests performed using wood pellets with a heating capacity of 4,9 kWh/kg.
The above information was obtained during product homologation tests performed at independent
laboratories accredited for pellet unit tests.
Содержание Hidro 12
Страница 18: ...12 Figure 11 specifies the basic requirements for installing the chimney to the unit a b ...
Страница 102: ...96 ...
Страница 103: ...97 ...
Страница 104: ...98 ...
Страница 133: ...127 25 2 Flow chart Hidro 12 Flow chart 1 Lighting ...
Страница 134: ...128 ...
Страница 135: ...129 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...
Страница 136: ...130 25 3 Flow chart Hidro 17 and Hidro 23 Flow chart 1 Lighting ...
Страница 137: ...131 ...
Страница 138: ...132 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...