9
5.
Installing the free-standing
pellet
fire
Before installing, please perform the following steps:
•
Upon reception, check the product for completeness and to determine that is does
not show any damage signs. Any damages or defects should be checked before the
unit is installed;
•
The unit is equipped with four adjustable height feet at the base which allow for a
simple regulation when installed on a non-flat surface;
Figure 8 - Adjustable feet
•
Remove the instruction manual from the package and hand it over to the client;
•
Connect an 80mm wide (Hidro 12) or 100mm wide (Hidro 17 or Hidro 23) duct
between the combustion gas output and the outgoing fume extraction duct of the
building (e.g., chimney) – check diagrams point 5;
•
If a tube is used for combustion air inlet from the outside, it shall be no longer than
60cm horizontally or present offsets (such as bends);
•
Perform the hydraulic installation;
•
Connect the 230VAC power cable to a grounded socket;
•
The surface of the unit where the hot air outlet is located must be facing the area
to be heated;
•
The unit's remote control has a programmable thermostat. As an option, a
conventional external programmer may be used (not included) to automatically setup
the unit's operating periods. This should be connected through cable to the optional
230VAC programmer plug (not provided).
Содержание Hidro 12
Страница 18: ...12 Figure 11 specifies the basic requirements for installing the chimney to the unit a b ...
Страница 102: ...96 ...
Страница 103: ...97 ...
Страница 104: ...98 ...
Страница 133: ...127 25 2 Flow chart Hidro 12 Flow chart 1 Lighting ...
Страница 134: ...128 ...
Страница 135: ...129 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...
Страница 136: ...130 25 3 Flow chart Hidro 17 and Hidro 23 Flow chart 1 Lighting ...
Страница 137: ...131 ...
Страница 138: ...132 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...