91
The tubes through which the gases and the respective turbulators circulate must be
cleaned. To do that, open the cover located in the upper part of the equipment (Figure
56-a and Figure 56-b) and remove the 4 knobs that fix the upper cover (Figure 56-c
and Figure 56-d). Then pull the turbulators upwards (Figure 56-e). A hoover should be
used to clean this area (Figure 56-f) and the inside of the pipes can be cleaned with a
steel brush. The removed turbulators should also be cleaned with a steel brush).
To put the turbulators back on, proceed in the opposite way to that shown in the
figures.
a)
b)
c) d)
e) f)
Figure 56 - Cleaning the air flow pipes and turbulators
Содержание Hidro 12
Страница 18: ...12 Figure 11 specifies the basic requirements for installing the chimney to the unit a b ...
Страница 102: ...96 ...
Страница 103: ...97 ...
Страница 104: ...98 ...
Страница 133: ...127 25 2 Flow chart Hidro 12 Flow chart 1 Lighting ...
Страница 134: ...128 ...
Страница 135: ...129 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...
Страница 136: ...130 25 3 Flow chart Hidro 17 and Hidro 23 Flow chart 1 Lighting ...
Страница 137: ...131 ...
Страница 138: ...132 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...