68
THE MAINTENANCE FAULT (“SERVICE” MESSAGE ON THE DISPLAY) MEANS
THAT THE STOVE HAS MORE THAN 2100 HOURS IN SERVICE. THE CUSTOMER
MUST HAVE THE EQUIPMENT SERVICED AND ONLY THEN RESET THE HOUR
METER TO ELIMINATE THE FAULT MESSAGE. THIS DOES NOT INFLUENCE THE
NORMAL OPERATION OF THE EQUIPMENT; IT IS ONLY A WARNING.
WARNING!
TO SWITCH OFF THE APPLIANCE IN AN EMERGENCY, YOU SHOULD NORMALLY
SHUT DOWN THE EQUIPMENT.
WARNING!
THE APPLIANCE WILL BE HOT DURING OPERATION, SO THAT CARE SHOULD
BE TAKEN ESPECIALLY WITH THE DOOR GLASS AND THE DOOR HANDLE.
Lack of voltage
supply
Er15
Lack of voltage supply
for more than 50 min
-
Check supply voltage with your
electricity supplier
-
Check the simultaneous use of
electrical appliances
-
In the event of a short power
failure (<10s) the stove continues
to operate normally
-
If the system was in the ON state
and the power failure occurs for
more than 10s and less than 50
min, the stove will switch on after
blackout
Communication
error RS485
Er16
- Check connection between board
and display
Open door error
(First Advance 12kW
only)
Er44
Door opens for 60 sec
- Close the door - remove the error
- Air mass sensor damage
Service
Service
Maximum
Hours:
2100
hr
(T66)
planned
for
maintenance
achieved
- Contact your installer for
occasional preventive maintenance
of the equipment
Содержание Hidro 12
Страница 18: ...12 Figure 11 specifies the basic requirements for installing the chimney to the unit a b ...
Страница 102: ...96 ...
Страница 103: ...97 ...
Страница 104: ...98 ...
Страница 133: ...127 25 2 Flow chart Hidro 12 Flow chart 1 Lighting ...
Страница 134: ...128 ...
Страница 135: ...129 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...
Страница 136: ...130 25 3 Flow chart Hidro 17 and Hidro 23 Flow chart 1 Lighting ...
Страница 137: ...131 ...
Страница 138: ...132 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...