Table 12.82. Register 0x0231 P0 Factional Division Enable
Reg Address
Bit Field
Type
Name
Description
0x0231
3:0
R/W
P0_FRACN_MODE
P0 (IN0) input divider fractional mode.
Must be set to 0xB for proper operation.
0x0231 4 R/W P0_FRAC_EN P0 (IN0) in-
put divider fractional enable.
0: Integer-only division.
1: Fractional (or Integer) division.
Table 12.83. Register 0x0232 P1 Factional Division Enable
Reg Address
Bit Field
Type
Name
Description
0x0232
3:0
R/W
P1_FRACN_MODE
P1 (IN1) input divider fractional mode.
Must be set to 0xB for proper operation.
0x0232 4 R/W P1_FRAC_EN P1 (IN1) in-
put divider fractional enable.
0: Integer-only division.
1: Fractional (or Integer) division.
Table 12.84. Register 0x0233 P2 Factional Division Enable
Reg Address
Bit Field
Type
Name
Description
0x0233
3:0
R/W
P2_FRACN_MODE
P2 (IN2) input divider fractional mode.
Must be set to 0xB for proper operation.
0x0233 4 R/W P2_FRAC_EN P2 (IN2) in-
put divider fractional enable.
0: Integer-only division.
1: Fractional (or Integer) division.
Table 12.85. Register 0x0234 P3 Factional Division Enable
Reg Address
Bit Field
Type
Name
Description
0x0234
3:0
R/W
P3_FRACN_MODE
P3 (IN3) input divider fractional mode.
Must be set to 0x0B for proper operation
0x0234 4 R/W P3_FRAC_EN P3 (IN3) in-
put divider fractional enable.
0: Integer-only division.
1: Fractional (or Integer) division.
Si5386 Rev. E Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
99
Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 9, 2021
99