Table 12.171. 0x0A40 N2 Dynamic Phase Adjust Step Size
Reg Address
Bit Field
Type
Name
Description
0x0A40
7:0
R/W
N2_PHASE_STEP
N2 step size from 1 to 255 in units of Tvco, the VCO
period.
Table 12.172. 0x0A41 N2 Dynamic Phase Adjust Step Size Count
Reg Address
Bit Field
Type
Name
Description
0x0A41
7:0
R/W
N2_PHASE_COUNT
Lower byte of number of N2 step size changes.
0x0A42
15:8
R/W
N2_PHASE_COUNT
Upper byte of number of N2 step size changes.
Table 12.173. 0x0A3 N2 Dynamic Phase Adjust Command
Reg Address
Bit Field
Type
Name
Description
0x0A43
0
R/W
N2_PHASE_INC
Writing a 1 initiates a phase increment.
0x0A43
1
R/W
N2_PHASE_DEC
Writing a 1 initiates a phase decrement.
The following tables for N3 dynamic phase adjust work the same as N0 dynamic phase adjust.
Table 12.174. 0x0A44 N3 Dynamic Phase Adjust Step Size
Reg Address
Bit Field
Type
Name
Description
0x0A44
7:0
R/W
N3_PHASE_STEP
N3 step size from 1 to 255 in units of Tvco, the VCO
period.
Table 12.175. 0x0A45 N3 Dynamic Phase Adjust Step Size Count
Reg Address
Bit Field
Type
Name
Description
0x0A45
7:0
R/W
N3_PHASE_COUNT
Lower byte of number of N3 step size changes.
0x0A46
15:8
R/W
N3_PHASE_COUNT
Upper byte of number of N3 step size changes.
Table 12.176. 0x0A47 N3 Dynamic Phase Adjust Command
Reg Address
Bit Field
Type
Name
Description
0x0A47
0
R/W
N3_PHASE_INC
Writing a 1 initiates a phase increment.
0x0A47
1
R/W
N3_PHASE_DEC
Writing a 1 initiates a phase decrement.
The following tables for N4 dynamic phase adjust work the same as N0 dynamic phase adjust.
Table 12.177. 0x0A48 N4 Dynamic Phase Adjust Step Size
Reg Address
Bit Field
Type
Name
Description
0x0A48
7:0
R/W
N4_PHASE_STEP
N4 step size from 1 to 255 in units of Tvco, the VCO
period.