Register Name
Hex Address
[Bit Field]
Function
SYSINCAL_FLG
0x0011[0]
SYSINCAL sticky bit. Sticky bits will remain asserted until written
with a zero to clear.
LOSXAXB_FLG
0x0011[1]
LOS status monitor sticky bits for XAXB. Sticky bits will remain
asserted when a LOS event occurs until cleared. Writing zero to
the bit will clear it.
LOS_EN
0x002C[3:0]
LOS monitor enable for IN3, IN2, IN1, IN0. Allows disabling the
monitor if unused.
0: Disable LOS Detection
1: Enable LOS Detection (default)
LOSXAXB_DIS
0x002C[4]
Enable LOS detection on the XAXB inputs.
0: Enable LOS Detection (default)
1: Disable LOS Detection
LOS_TRG_THR
0x002E[7:0]-0x0035[7:0]
Sets the maximum period at the output of the P divider for
IN3,2,1,0. A single period larger than this threshold will assert
LOS. A continuous run of periods that are less than this period
and more than the minimum period set by LOS_CLR_THR will
de-assert LOS.
LOS_CLR_THR
0x0036[7:0]-0x003D[7:0]
Sets the minimum period at the output of the P divider for
IN3,2,1,0. A single period smaller than this threshold will assert
LOS. A continuous run of periods that are greater than this period
and less than the maximum period set by LOS_CLR_THR will
de-assert LOS.
LOS_INTR_MSK
0x0018[3:0]
This is the LOS interrupt mask, which can be cleared to trigger an
interrupt on the INTR pin if an LOS occurs for IN0-3.
Si5386 Rev. E Reference Manual • Clock Inputs
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
27
Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 9, 2021
27