2. Modes of Operation
After initialization, the DSPLL will operate in one of the following modes: Free run, Lock-Acquisition, Locked, VCO Freeze, or Holdover.
These modes are described further in the sections below.
No valid
input clocks
selected
Lock Acquisition
(Fast Lock)
Locked
Mode
Holdover
Mode
Phase lock on
selected input
clock is achieved
An input is
qualified and
available for
selection
No valid input
clocks available
for selection
Free Run
Valid input clock
selected
Reset and
Initialization
Power-Up
Selected input
clock fails
Yes
No
Holdover
History
Valid?
Other Valid
Clock Inputs
Available?
No
Yes
Input Clock
Switch
VCO Freeze
State
An input is
qualified and
available for
selection
Figure 2.1. Modes of Operation