External XO: The figure below shows the output clocks. Similar to the input clocks, the output clocks have vias that immediately go to
a buried layer with a ground plane above them and a ground flooded bottom layer. There is ground flooding between the clock output
pairs to reduce crosstalk. There should be a line of vias through the ground flood on either side of the output clocks to ensure that the
ground flood immediately next to the differential pairs has a low inductance path to the ground plane on layers 3 and 6.
Figure 9.7. External XO: Output Clocks (Layer 7)
Si5386 Rev. E Reference Manual • XO and Device Circuit Layout Recommendations
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
71
Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 9, 2021