Table 12.128. Register 0x0532-0x0534 Holdover Cycle Count
Reg Address
Bit Field
Type
Name
Description
0x0532
7:0
R/W
HOLD_15M_CYC_COUNT
Value calculated in CBPro.
0x0533
15:8
R/W
HOLD_15M_CYC_COUNT
0x0534
23:16
R/W
HOLD_15M_CYC_COUNT
Table 12.129. Register 0x0535 Force Holdover
Reg Address
Bit Field
Type
Name
Description
0x0535
0
R/W
FORCE_HOLD
Force the device into Holdover
mode. Used to hold the device out-
put clocks while retraining an up-
stream input clock.
0: Normal Operation
1: Force Holdover/Free run Mode:
HOLD_HIST_VALID = 0 =>Free
run Mode
HOLD_HIST_VALID = 1 =>Hold-
over Mode
Table 12.130. Register 0x0536 Input Clock Switching Control
Reg Address
Bit Field
Type
Name
Description
0x0536
1:0
R/W
CLK_SWITCH_MODE Selects manual or automatic
switching modes. Automatic mode
can be Revertive or Non-revertive.
00: Manual (default), 01: Automatic
Non-revertive,
02: Automatic Revertive, 03: Re-
served
0x0536
2
R/W
HSW_EN
Enable Hitless Switching.
0: Disable Hitless switching
1: Enable Hitless switching (phase
buildout enabled) (default)
Table 12.131. Register 0x0537 Input Fault Masks
Reg Address
Bit Field
Type
Name
Description
0x0537
3:0
R/W
IN_LOS_MSK
Enables the use of IN3 - IN0 LOS
status in determining a valid clock
for automatic input selection.
0: Use LOS in automatic clock
switching logic (default)
1: Mask (ignore) LOS from auto-
matic clock switching logic