Reg Address
Bit Field
Type
Name
Description
0x000C
5
R
SMBUS_TIMEOUT
1 if there is currently an SMB Bus
Timeout error.
See
for more information.
Table 12.10. Register 0x000D Out-of-Frequency (OOF) and Loss-of Signal (LOS) Status
Reg Address
Bit Field
Type
Name
Description
0x000D
3:0
R
LOS
1 if IN3 - IN0 is currently LOS
0x000D
7:4
R
OOF
1 if IN3 - IN0 is currently OOF
See
for more information.
• IN0: LOS 0x000D[0], OOF 0x000D[4]
• IN1: LOS 0x000D[1], OOF 0x000D[5]
• IN2: LOS 0x000D[2], OOF 0x000D[6]
• IN3/FB_IN: LOS 0x000D[3], OOF 0x000D[7]
Table 12.11. Register 0x000E Holdover (HOLD) and Loss-of-Lock (LOL) Status
Reg Address
Bit Field
Type
Name
Description
0x000E
1
R
LOL
1 if the DSPLL is currently out of
lock
0x000E
5
R
HOLD
1 if the DSPLL is currently in Hold-
over or Free run
See
for more information.
Table 12.12. Register 0x000F DSPLL Calibration Status
Reg Address
Bit Field
Type
Name
Description
0x000F
5
R
CAL
1 if the DSPLL internal calibration
is currently busy
See
for more information.
Table 12.13. Register 0x0011 Device Status Flags
Reg Address
Bit Field
Type
Name
Description
0x0011
0
R/W
SYSINCAL_FLG
Flag 1 if the device was in SYSINCAL
0x0011
1
R/W
LOSXAXB_FLG
Flag 1 if the XAXB reference clock showed LOS-
XAXB
0x0011
2
R/W
LOSREF_FLG
Flag 1 if the XAXB reference clock LOSREF
0x0011
3
R/W
XAXB_ERR_FLG
Flag 1 if the XAXB reference clock showed
XAXB_ERR
0x0011
5
R/W
SMBUS_TIMEOUT_FLG
Flag 1 if SMBUS_TMEOUT ws in error
These are sticky flag bits corresponding to the bits in register 0x000C. They are cleared by writing 0 to the bit that has been set. The
corresponding 0x000C register bit must be 0 to clear this sticky flag bit. See
for more information.
Si5386 Rev. E Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
78
Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 9, 2021