Table 3.10. Loss of Lock Status Monitor and Control Registers
Register Name
Hex Address
[Bit Field]
Function
LOL
0x000E[1]
Status bit that indicates if the DSPLL is locked to an input clock
LOL_FLG
0x0013[1]
Sticky bits for LOL register. Writing 0 to a sticky bit will clear it.
LOL_SET_THR
0x009E[7:4]
Configures the loss of lock set threshold in ppm.
LOL_CLR_THR
0x00A0[7:4]
Configures the loss of lock clear threshold in ppm.
LOL_TIMER_EN
0x00A2[1]
Allows bypassing the LOL clear delay timer.
0-bypassed, 1-enabled. Set by CBPro.
LOL_NOSIG_TIME
0x02B7[3:2]
Sets 417 μs as time without an input to assert LOL. Set by CBPro.
LOL_CLR_DELAY_DIV256
[ 0x00AC[4:0] 0x00AB[7:0]
0x00AA[7:0] 0x00A9[7:0] ]
This 29 bit timer sets the delay value for the LOL clear delay
timer. Set by CBPro.
FASTLOCK_EXTEND_EN
0x00E5[5]
Enables FASTLOCK_EXTEND.
FASTLOCK_EXTEND
[ 0x00ED[4:0] 0x00EC[7:0]
0x00EB[7:0] 0x00EA[7:0] ]
Set by CBPro to minimize phase transients when switching the
PLL bandwidth.
FASTLOCK_EXTEND_SCL
0x0294[7:4]
Set by CBPro.
LOL_SLW_VALWIN_SELX
0x0296[1]
Set by CBPro.
FASTLOCK_DLY_ONSW_EN
0x0297[1]
Set by CBPro.
FASTLOCK_DLY_ONSW
0x02A9[19:0]
Set by CBPro.
FASTLOCK_DLY_ONLOL_EN
0x0299[1]
Set by CBPro.
FASTLOCK_DLY_ONLOL
0x029D[19:0]
Set by CBPro.
The settings in the table above are handled by ClockBuilder Pro. Manual settings should be avoided.