Section 04 ENGINE MANAGEMENT (SDI)
Subsection 03 (COMPONENT INSPECTION, REPLACEMENT AND ADJUSTMENT)
BATTERY
Manual Start Models
These models are equipped with a YT4L-BS type
battery that requires a specific charging procedure
at predelivery.
Battery Charge Testing
WARNING
Always wear safety glasses and charge in a
ventilated area.
Never charge or boost battery while installed
on vehicle.
Do not open the sealed caps during charging.
Do not place battery near open flame.
These sealed batteries have to be tested with a
voltmeter.
Batteries with a voltage of 12.8 volts and above,
no charge is required
Batteries with a voltage of 12.7 volts and below
must be charged as follows:
BATTERY
TYPE
STANDARD
CHARGE
QUICK CHARGE
YT4L-BS
0.3 Amps/hour
for
5 to 10 hours
3.0 Amps/hour
for
30 min.
Electric Start Models
Refer to CHARGING SYSTEM section for the
charging procedure of the battery.
CAPACITOR
Manual Start Models
A35C3SD
1
1. Capacitor
WARNING
Capacitor may be charged. Once discharged,
a transient recovery voltage may be generat-
ed in the capacitor after a while. Always dis-
charge capacitor before servicing.
Removal
Remove the 30 A fuse.
Connect a test light to capacitor terminals during
a complete minute to discharge capacitor.
WARNING
Do not short-circuit both capacitor terminals.
Disconnect capacitor terminals and unfasten ca-
pacitor.
Inspection
Visual Inspection
Check for pin holes in the pressure relief valve on
top of capacitor. If any pin hole is present, discard
capacitor.
Charge Hold Test
Connect a 12 V test lamp to capacitor terminals
during a complete minute to discharge capacitor.
Connect a switch (in OFF position) between a 12 V
battery positive post and the capacitor positive
post. Connect the battery negative post to the
capacitor negative post. Turn on the switch for 2
seconds. Disconnect the capacitor from the bat-
tery.
Note battery voltage.
WARNING
Always respect the polarity when connecting
the capacitor.
Wait 5 minutes, then measure capacitor voltage.
It must be within 1 V maximum of battery voltage.
If in doubt, proceed with the following residual
voltage test.
Residual Voltage Test
Connect a 12 V test lamp to capacitor terminals
during a complete minute to discharge capacitor.
mmr2005-126
157
Содержание 2005 MACH Z
Страница 2: ......
Страница 3: ...2005 Shop Manual RT SERIES BOMBARDIER RECREATIONAL PRODUCTS INC...
Страница 40: ...Section 02 ENGINE Subsection 02 AIR INTAKE SYSTEM AIR INTAKE SYSTEM A35C02S mmr2005 149 15...
Страница 220: ...Section 06 DRIVE SYSTEM Subsection 03 DRIVEN PULLEY A35D1BA Install circlip mmr2005 133 207...
Страница 339: ...Section 11 WIRING DIAGRAMS Subsection 01 WIRING DIAGRAMS A35Z01S 2005 MACH Z RT SUMMIT RT ENGINE 334 MMR2005 146...
Страница 340: ...NOTES...
Страница 341: ...NOTES...
Страница 342: ...2005 MACH Z RT SUMMIT RT A35Z02...
Страница 343: ......