Operation
5-20
SITRANS FM Intermag 2 Flow Transmitter
Operating Manual - A5E00102775-03
Menu
code
Device function,
Parameters
Description
Factory setting
(display only)
Setting options
6.6
Zero Trim
6.6.1
Zero Flow Cor.
Correction value for the
zero point of the flow
measurement in m/s
0
-1 to +1 m/s
6.6.2
Start Correct.
Start of zero calibration;
The medium must be at
a standstill during
calibration!
6.7
Trim Parameter
Values in
6.7.2.4
can only
be written if no SmartPlug
data can be read
6.7.1
Cal.factor
User-specific calibration
factor;
the measured flow value is
multiplied by this factor
before output
(affects all outputs,
totalizers and display)
1.0
0.5 to 1.5
6.7.2
CFH
5
Calibration value for
hydraulic reference point
at 1m/s
400
6.7.3
ZPH
5
Calibration value for
hydraulic zero point
0
6.7.4
Excitat.Freq.
5
Magnetic field current
frequency depending on
sensor and power supply
6 Hz or f/8
3 Hz or f/16,
6 Hz or f/8,
12 Hz or f/4
6.7.5
EmptyTube Det.
Adjustment of electrode
immersion check
Act.Value El1
Display of actual control
value of electrode El1 in %
of end value
Act.Value El2
Display of actual control
value of electrode El12 in
% of end value
Threshold
Threshold of diagnostic
function ”Immersion
check” for ”Tube empty”
message (see table 5-2
and menu
2.3
)
33 %
5 to 95 %
2
Parameters apply only to devices with 20 mA/Hart communication and digital input
(7ME5033-2xxxx)
5
Parameters apply only to devices with sensors without SmartPLUG
Table 5-1
Functions of the SITRANS FM Intermag 2 transmitter
Содержание SITRANS F M Intermag 2
Страница 2: ......
Страница 8: ...SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 I 4 ...
Страница 9: ...1 1 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 Information for the User 1 ...
Страница 111: ...Appendix 7 3 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 113: ...Appendix 7 5 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 114: ...Appendix 7 6 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 115: ...Appendix 7 7 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 116: ...Appendix 7 8 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 117: ...Appendix 7 9 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 118: ...Appendix 7 10 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 119: ...Appendix 7 11 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 120: ...Appendix 7 12 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 128: ...Appendix 7 20 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 129: ...Appendix 7 21 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...