Operation
5-12
SITRANS FM Intermag 2 Flow Transmitter
Operating Manual - A5E00102775-03
Menu
code
Device function,
Parameters
Description
Factory setting
(display only)
Setting options
3.
Meas.Functions
3.1
Flow
3.1.1
Engr. Unit
Engineering unit for
volume flow
or
mass flow
When you select a unit
of mass flow (see right
column), you must enter
the actual medium
density (menu
3.1.4
).
DN 2 ... 12: l/h
DN >12:
m
3
/h
m
3
/s, m
3
/min,
m
3
/h, m
3
/d, l/s,
l/min, l/h, Ml/d,
ft
3
/s, ft
3
/min,
ft
3
/h, ft
3
/d, gal/s,
gal/min, gal/h,
gal/d, Mgal/d,
ImpGal/s,
ImpGal/min,
ImpGal/h,
ImpGal/d
g/s, g/min, kg/s,
kg/min, kg/h,
kg/d, Ton/min,
Ton/h, Ton/d,
lb/s, lb/min, lb/h,
lb/d, Ston/min,
Ston/h, Ston/d,
Lton/d
3.1.2
Flow URV
Upper range value (URV)
At the analog output the
amount of the measured
value in the range 0 up to
URV is displayed linear to
the current range 4 to
20mA, at the digital output
1 to the frequency range 0
to end frequency
Depending on
the nominal
width according
to 2...3m/s
Depending on
the nominal
width (according
to 0.25 to
12m/s)
3.1.3
Limits
Absolute values in flow
units from menu
3.1.1
3.1.3.1
Lo Alarm Limit
Lower alarm limit
(the lower alarm limit must
be smaller than the upper
alarm limit)
10% of the URV
(depending on
the nominal
width according
to 0.2...0.3m/s )
Depending on
the nominal
width (according
to -13m/s to
+13m/s)
3.1.3.2
Hi Alarm Limit
Upper alarm limit
(the upper alarm limit must
be greater than the lower
alarm limit)
90% of the URV
(depending on
the nominal
width according
to 1.8...2.7m/s )
Depending on
the nominal
width (according
to -13m/s to
+13m/s)
3.1.3.3
Hysteresis
Hysteresis for limit values
in % of full scale value
1 %
0 to 20 %
3.1.4
Density
Density of the medium
Engr. Unit
Engineering unit of the
medium density
kg/m
3
g/cm
3
, kg/m
3
,
lb/gal, kg/l, g/l,
lb/in
3
, lb/lmpgal
Density
Density value for
calculation of mass flow
+1000.00 kg/m
3
200 to
5000 kg/m
3
Содержание SITRANS F M Intermag 2
Страница 2: ......
Страница 8: ...SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 I 4 ...
Страница 9: ...1 1 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 Information for the User 1 ...
Страница 111: ...Appendix 7 3 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 113: ...Appendix 7 5 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 114: ...Appendix 7 6 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 115: ...Appendix 7 7 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 116: ...Appendix 7 8 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 117: ...Appendix 7 9 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 118: ...Appendix 7 10 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 119: ...Appendix 7 11 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 120: ...Appendix 7 12 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 128: ...Appendix 7 20 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Страница 129: ...Appendix 7 21 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...