A.9 Information List
668
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015
68
Clock Synchronization Error
(Clock SyncError)
Device, General
OUT
On
Off
*
*
LED
BO
69
Daylight Saving Time (DayLight-
SavTime)
Device, General
OUT
On
Off
*
*
LED
BO
70
Setting calculation is running
(Settings Calc.)
Device, General
OUT
On
Off
*
*
LED
BO
160
22
1
Yes
71
Settings Check (Settings Check)
Device, General
OUT
*
*
*
LED
BO
72
Level-2 change (Level-2 change) Device, General
OUT
On
Off
*
*
LED
BO
110
Event lost (Event Lost)
Device, General
OUT_
Ev
on
*
LED
BO
135
130
1
No
113
Flag Lost (Flag Lost)
Device, General
OUT
on
*
m
LED
BO
135
136
1
Yes
125
Chatter ON (Chatter ON)
Device, General
OUT
On
Off
*
*
LED
BO
135
145
1
Yes
126
Protection ON/OFF (via system
port) (ProtON/OFF)
P.System Data 2
IntSP
On
Off
*
*
LED
BO
127
79 ON/OFF (via system port) (79
ON/OFF)
79M Auto Recl.
IntSP
On
Off
*
*
LED
BO
140
Error with a summary alarm
(Error Sum Alarm)
Device, General
OUT
On
Off
*
*
LED
BO
160
47
1
Yes
144
Error 5V (Error 5V)
Device, General
OUT
On
Off
*
*
LED
BO
145
Error 0V (Error 0V)
Device, General
OUT
On
Off
*
*
LED
BO
146
Error -5V (Error -5V)
Device, General
OUT
On
Off
*
*
LED
BO
147
Error Power Supply (Error Pwr-
Supply)
Device, General
OUT
On
Off
*
*
LED
BO
160
Alarm Summary Event (Alarm
Sum Event)
Device, General
OUT
On
Off
*
*
LED
BO
160
46
1
Yes
161
Failure: General Current Supervi-
sion (Fail I Superv.)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
160
32
1
Yes
162
Failure: Current Summation (Fail-
ure
Σ
I)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
135
182
1
Yes
163
Failure: Current Balance (Fail I
balance)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
135
183
1
Yes
167
Failure: Voltage Balance (Fail V
balance)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
135
186
1
Yes
169
VT Fuse Failure (alarm >10s) (VT
FuseFail>10s)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
135
188
1
Yes
170
VT Fuse Failure (alarm instanta-
neous) (VT FuseFail)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
170.0001
>25-group 1 activate (>25-1 act)
SYNC function 1
SP
On
Off
*
LED BI
170.0001
>25-group 2 activate (>25-2 act)
SYNC function 2
SP
On
Off
*
LED BI
170.0001
>25-group 3 activate (>25-3 act)
SYNC function 3
SP
On
Off
*
LED BI
170.0001
>25-group 4 activate (>25-4 act)
SYNC function 4
SP
On
Off
*
LED BI
170.0043
>25 Sync. Measurement Only
(>25 Measu. Only)
SYNC function 1
SP
On
Off
*
LED BI
170.0043
>25 Sync. Measurement Only
(>25 Measu. Only)
SYNC function 2
SP
On
Off
*
LED BI
170.0043
>25 Sync. Measurement Only
(>25 Measu. Only)
SYNC function 3
SP
On
Off
*
LED BI
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
a
u
lt)
Log ON
/O
FF
G
round
Fault Log ON/
O
FF
Mar
ked in Osc
il
l.
Recor
d
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
fo
rm
a
tio
n
Num
b
er
Dat
a
Un
it
General Interro
gat
ion
Содержание siprotec SJ62
Страница 3: ...3 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 9: ...Preface 9 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 21: ...Contents 19 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 35: ...1 Introduction 33 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 365: ...2 Functions 363 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 443: ...3 Mounting and Commissioning 441 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 529: ...4 Technical Data 527 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 699: ...A Appendix 697 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 701: ...Literature 699 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 714: ...Index 712 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...
Страница 715: ...Index 713 SIPROTEC 4 7SJ62 63 64 Handbuch C53000 G1140 C147 A Edition 07 2015 ...