Configure doors
27
Building Technologies
052_SiPass_Entro_6_5_A24205-A335-B318_e_en
Fire Safety & Security Products
10.03.2010
14.
Select the Motor lock stays locked… check box if the motor lock should remain
locked until the first person unlocks the door, e.g. in the morning.
15.
Enter whether the internal buzzer should sound on key presses or not.
16.
Select the Allow remote control of this door check box if the door will be
operated from a PC, e.g. opened, via the Door and event monitor program.
17.
You can select how the exit request input will act (pulsed):
Marked means that the door is unlocked for the maximum opening time
from the moment the input is activated.
Unmarked results in the opening time starting from the moment the input
becomes inactive. I e the door can be externally controlled and the lock
relay can be activated longer than the opening time.
Select if this door allows for a temporary changing of security levels to
Unlocked or Group code by a caretaker. See section Caretaker functions
[
62] on how this is managed at the door.
18.
If lift control is applied, you may go to the IOR6 Relays tab and activate the
desired relays during certain time zones. By activating the relay for a specific
floor during a specific time zone, the floor will be accessible without the use of
cards or code.
19.
Click OK.
20.
Enter information about the next door in the same way.
If you select a door and right-click you are able to Edit settings – or Show persons