Component
Description
Smart / Active / Basic
Line Module
Line Modules provide the central power supply to the DC link.
Single / Double Motor Module Motor Modules draw their power from the DC link to supply the connec‐
ted motors.
HF Motor Module
Operates as inverter and provides the energy for the
connected motor - High Frequency Drive.
S120 Combi
Compact and robust multi-axis Power Module for the machine tool.
Power Modules
Power Modules provide the energy for the connected motor.
SINAMICS S120, system components, chassis format
Smart / Active / Basic Line
Module
Line Modules provide the central power supply to the DC link.
Motor Module
Motor Modules draw their power from the DC link to supply the connec‐
ted motors.
SINAMICS S120, additional system components
SMC10 / 20 / 30 / 40
Cabinet-mounted Sensor Modules are used when a motor with a DRIVE-
CLiQ interface is not available and when external encoders are required
in addition to the motor encoder.
SME20 / 25
SME120 / 125
Measuring systems outside the control cabinet can be connected directly
to the Sensor Module External.
DMC20/DME20
DRIVE-CLiQ Hub Modules are used to implement star-shaped distribution
of a DRIVE‑CLiQ line.
TM15-2/TM31
The number of available digital inputs and outputs within a drive system
can be expanded using a Terminal Module.
TM41
The number of available digital inputs and outputs within a drive system
can be expanded using a Terminal Module; an incremental encoder can
also be emulated.
TM120
The TM120 Terminal Module is used for temperature evaluation with
protective separation. It can be used for 1FN, 1FW6 and third-party mo‐
tors.
CUA31
Adapter to connect a Power Module to the NCU.
VSM10
The VSM10 Voltage Sensing Module is capable of measuring the line
voltage waveform precisely and helps Line Modules to continue func‐
tioning properly under difficult supply conditions, for example, in the
case of extreme voltage fluctuations or brief supply interruptions.
HLA
Controls (open-loop and closed-loop) electrohydraulic control valves in
hydraulic linear axes in conjunction with SINUMERIK ONE
S120M
This is the distributed version of the modular SINAMICS S120 drive sys‐
tem.
Additional information
Additional information about Line, Motor and Power Modules is provided in:
• Booksize Power Units Equipment Manual
• Chassis Power Units Equipment Manual
• AC DRIVE Equipment Manual
Connecting
8.6 DRIVE-CLiQ components
NCU 1740
Equipment Manual, 10/2021, A5E51087503B AA
67
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...