Note
The fast digital inputs/outputs must be shielded.
8.10.3
Connecting digital inputs/outputs
Cable specification
Table 8-21
Cable specification at X122 / X132 / X142
Features
Version
Connector type
14-pin spring-loaded terminals
Number of cables that can be connected 1
Connection option
0.2 to 1.5 mm
2
Max. current carrying capacity
6 A
Max. cable length
30 m
Table 8-22
Connectable conductor cross-sections
Connectable conduc‐
tor cross-sections
Rigid
Flexible
Flexible, with end sleeve without plastic sleeve
Flexible, with end sleeve with plastic sleeve
AWG / kcmil
0.2 to 1.5 mm
2
0.2 to 1.5 mm
2
0.25 to 1.5 mm
2
0.25 to 0.75 mm
2
24 to 16
Stripped length
10 mm
Tool
Screwdriver
0.4 x 2.0 mm
Note
To achieve optimum interference suppression, shielded cables must be used to connect
measuring inputs or BEROs.
The following cable lugs may be used:
• Crimped cable lug to DIN 46234
• Pressed cable lug to DIN 46235
• Tube-type cable lug to SN 71322
• Tube-type cable lug "Klauke R Series", UL Category ZMVV
Connecting
8.10 Digital inputs/outputs
NCU 1740
84
Equipment Manual, 10/2021, A5E51087503B AA
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...