Internal supply voltage (P24OUT)
The internal power supply for the digital inputs (X111, X222, X333: Pin 2) is derived from the
general power supply of module X1, pin 2 (P24).
Technical data
Table 12-24 Electrical specification of the digital inputs:
Digital inputs
min.
max.
Nominal
High-level voltage (U
H
)
15 V
30 V
24 V
Input current I
IN
at V
H
2 mA
15 mA
-
Low-level voltage (U
L
)
-3 V
5 V
0 V
Signal delay time T
PHL
0.5 ms
3 ms
-
Digital outputs
Characteristics
• No galvanic isolation.
• Protection against: Short-circuit, overtemperature, and loss of ground.
• Automatic disconnection in case of undervoltage.
Terminal assignment for the digital outputs
The following figure shows an example of the terminal assignment for the digital outputs on
connector X111. Connectors X222 and X333 are assigned analogously.
([WSRZHUVXSSO\
9'&VWDELOL]HG
;;;
3LQQXPEHU
'ULYHU
'ULYHU
'ULYHU
5HOD\
33'31
9
9
'2&20[
:
:
:
:
1
(M)
0
Connectable components
12.2 PP 72/48D PN
NCU 1740
Equipment Manual, 10/2021, A5E51087503B AA
123
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...