• The 3 plug-in connectors for the digital inputs and outputs are 50-pin terminal posts for
connecting ribbon cables.
• Terminal strip converters can be used, or the direct connection of distribution boards, for
example, is possible.
An external power supply unit (24 V DC) is required to supply the module and the digital outputs.
Illustration
①
Switch S1
②
LEDs H1 ... H6
③
X111
Digital input/outputs 1
④
X222
Digital input/outputs 2
⑤
X333
Digital input/outputs 3
⑥
Grounding screw
⑦
X1
Power supply connection
⑧
X2, port 1 PROFINET interface
⑨
X2, port 2 PROFINET interface
⑩
Mounting plate
Figure 12-7
PP 72/48D PN I/O module
Connectable components
12.2 PP 72/48D PN
NCU 1740
110
Equipment Manual, 10/2021, A5E51087503B AA
Содержание SINUMERIK ONE NCU 1740