Bit
Signal name
Message
2
Diag_2
Overload DO byte 5/4
1
Diag_1
Overload DO byte 3/2
0
Diag_0
Overload DO byte 1/0
Note
The "alive and well" counter is a 3-bit modulo counter at the PP application level. The PP
application can be monitored using this counter. Failure of the application software does not
generally result in a communication failure, as this is developed in a hardware-supported
manner. The watch dog switches off the digital outputs, while the inputs remain at their last set
values.
Table 12-64 Overview of the messages in byte 1, depending on the "alive and well" counter
"alive and
well" counter
Value
byte 1
Message
0
0
Reserved
1
Temperature value
2
0
No error
1
Impermissible input voltage in the temperature measurement mode
2
Reserved
3
Overload at the outputs
4
Incorrect operating mode selection
5
Internal error, system error
6
Range exceeded at the inputs
7
Range exceeded at the outputs
3 ... 7
0
Reserved
Table 12-65 Elimination of error for "alive and well" counter status "2"
Value
byte 1
Cause
Effect
Remedy
1
In the temperature measure‐
ment operating mode, an in‐
put voltage is too high. The
hardware may become dam‐
aged/destroyed as a result.
The "PNFault" LED is activated.
The outputs are switched off.
1)
The value 0x80 is stored in status byte 1.
It is essential that a Pt100 element is con‐
nected to terminals 3-4 or 7-8.
The module must be restarted with Power
ON after the error has been eliminated.
2
Reserved
-
-
3
Overload at the outputs
The "PNFault" LED is activated.
The outputs are switched off.
1)
The value 0x80 is stored in status byte 1.
Check the loads at the analog output.
The module must be restarted with Power
ON after the error has been eliminated.
4
Incorrect operating mode se‐
lection, e.g. temperature
measurement at the analog
outputs.
Selection of operating mode is rejected,
If selected correctly, the module switches
to cyclic operation.
Connectable components
12.3 PP 72/48D PN 2/2A PN
NCU 1740
154
Equipment Manual, 10/2021, A5E51087503B AA
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...