8.8
PROFINET
Application
Via the PROFINET interface, you can establish PROFINET IO communications networks between
the PLC of the control and the field devices.
• X150 supports RT and IRT
• X160 supports RT
Properties
The PROFINET interfaces X150 and X160 are separate interfaces.
The PROFINET interface X150 is equipped with an integrated 2-port switch and a TCP/IP address
for the 2 ports.
Pin assignment
For diagnostic purposes, the RJ45 sockets are each equipped with a green and an orange LED.
This allows the following status information about the respective PROFINET port to be displayed:
Table 8-11
Assignment of PROFINET interfaces X150, ports 1, 2 in the 10/100 MBit/s mode
Connector
Pin
Name
Type
Remark
/('
/('
1
TxD+
O
Transmit data
2
TxD-
3
RxD+
I
Receive data
4/5
GND
-
(terminated internally with 75 Ω; not re‐
quired for data transmission)
6
RD-
I
Receive data
7/8
GND
-
(terminated internally with 75 Ω; not re‐
quired for data transmission)
Shield
-
-
On connector housing
-
LED green
(Link)
-
Lit: 10 or 100 Mbit/s
Off: No or faulty connection
-
LED orange
(Activity)
-
Flashes: Data exchange
Off: No data exchange
Signal type: O = Output; I = Input
Connecting
8.8 PROFINET
NCU 1740
Equipment Manual, 10/2021, A5E51087503B AA
71
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...