Digital inputs
min.
max.
Nominal
Low-level voltage (U
L
)
-3 V
5 V
0 V
Signal delay time T
PHL
0.5 ms
3 ms
-
Signal delay time T
PHL
rapid inputs (X222: DI 3.0 to
3.7)
-
-
600 μs
Digital outputs
• Characteristics
– No galvanic isolation.
– Protection against: Short-circuit, overtemperature, and loss of ground.
– Automatic disconnection in case of undervoltage.
• Terminal assignment for the digital outputs:
The following figure shows an example of the terminal assignment for the digital outputs on
connector X111. Connectors X222 and X333 are assigned analogously.
([WSRZHUVXSSO\
9'&VWDELOL]HG
;;;
3LQQXPEHU
'ULYHU
'ULYHU
'ULYHU
5HOD\
33'$31
9
9
'2&20[
:
:
:
:
1
(M)
0
Figure 12-16
Terminal assignment for the digital outputs
NOTICE
Damage to the module
If the outputs are overloaded, the heat can melt the contacts.
Therefore, for a demand factor of 100%, a max. current of I
out
= 0.25 A at X111, X222, X333:
Pin 2, must not be exceeded.
• Technical data:
Connectable components
12.3 PP 72/48D PN 2/2A PN
NCU 1740
142
Equipment Manual, 10/2021, A5E51087503B AA
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...