Table 12-46 Electrical specification of the digital outputs
Digital outputs
min.
Standard
max.
nominal
High-level voltage (U
H
)
V
CC
- 3 V
1)
V
CC
24 V
Output current I
OUT
-
-
250 mA
2)
-
Voltage with low level (U
L
)
-
-
-
Output open
Leakage current at low level
-
50 μA
400 μA
-
Signal delay time T
PHL
-
0.5 ms
-
-
Maximum switching frequency
Resistive load
-
-
100 Hz
-
Inductive load
-
-
2 Hz
-
Lamp
-
-
11 Hz
-
•
1)
U
H_typical
= V
CC
- I
OUT
× R
ON
V
CC
: Current operating voltage
I
OUT
: Output current
Maximum short-circuit current: 4 A (max. 100 μs, V
CC
= 24 V)
R
ON
: Maximum internal resistance = 0.4 Ω
•
2)
Where demand factor is 100% (all outputs active)
• Incorrect connection causes neither high level nor destruction of the outputs.
12.3.4.5
Analog X3 inputs/outputs
Cable specification
• Connectors: 12-pin socket/plug combination
• Cable: shielded
– max. cable length: 30 m
– max. connectable core cross-section: 0.5 mm
2
Wiring analog inputs/outputs
NOTICE
Shield support
If the analog inputs/outputs are wired, a shielded lead must be used. The shield must be
supported.
Procedure:
1. Strip cable for analog signals.
2. Secure the stripped connection piece of the cable with the shield connection clamp.
Connectable components
12.3 PP 72/48D PN 2/2A PN
NCU 1740
Equipment Manual, 10/2021, A5E51087503B AA
143
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...