1
2
3
4
5
6
7
8
9
10 Default device name
off
on
on
off
off
off
off
off
pp72x48pn6
on
off
on
off
off
off
off
off
pp72x48pn5
off
off
on
off
off
off
off
off
pp72x48pn4
on
on
off
off
off
off
off
off
pp72x48pn3
off
on
off
off
off
off
off
off
pp72x48pn2
on
off
off
off
off
off
off
off
pp72x48pn1
off
off
off
off
off
off
off
off
pp72x48pn
Note
A newly set PROFINET address will only come into effect after power OFF/ON.
12.3.4.4
X111, X222 and X333 digital inputs/outputs
Cable specification
• Connectors: 50-pin ribbon cable connectors
50-pin insulation displacement connectors with cable grip, ribbon cables and terminal
converters
are required for connecting digital inputs and outputs.
• The required connecting cables (ribbon cables) must be provided by the user
.
• Max. cable length: 30 m
Pin assignment
Table 12-42 Pin assignment X111
Pin
Signal name
Type
Pin
Signal name
Type
1
M
GND
2
P24OUT
VO
3
DI 0.0
I
4
DI 0.1
I
5
DI 0.2
I
6
DI 0.3
I
7
DI 0.4
I
8
DI 0.5
I
9
DI 0.6
I
10
DI 0.7
I
11
DI 1.0
I
12
DI 1.1
I
13
DI 1.2
I
14
DI 1.3
I
15
DI 1.4
I
16
DI 1.5
I
17
DI 1.6
I
18
DI 1.7
I
19
DI 2.0
I
20
DI 2.1
I
21
DI 2.2
I
22
DI 2.3
I
23
DI 2.4
I
24
DI 2.5
I
25
DI 2.6
I
26
DI 2.7
I
27
Not assigned
-
28
Not assigned
-
Connectable components
12.3 PP 72/48D PN 2/2A PN
NCU 1740
138
Equipment Manual, 10/2021, A5E51087503B AA
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...