Pin assignment
Pin
Signal name
Signal type
Meaning
+/-
P24
VI
Power supply 24 V
+/-
P24
VI
M
M
VO
Ground
M
M
VO
Signal type: VI = voltage input;VO = voltage output
Note
The two "+" or "M" terminals are jumpered in the connector. This ensures the 24 V voltage is
looped through. The maximum current can be limited through the current carrying capacity of
the cable. The current carrying capacity of the cable depends, for example, on the type of cable
installation (cable duct, laying on a cable rack, etc.).
Wiring the screw terminal block
The 24 V DC load power supply required is wired to screw terminal block X124.
Connecting
8.5 Power supply
NCU 1740
62
Equipment Manual, 10/2021, A5E51087503B AA
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...