Name
Color
Status
Meaning
Activity
Yellow
Lit
Sending or receiving
Off
No activity
PROFINET address (S1)
The right logical address must be assigned to the I/O module for communication with PLC I/O
interface using the 10 bit DIP switch S1.
Table 7-87
Switch S1 settings
1
2
3
4
5
6
7
8
9
10 Device name
Meaning
on
on
on
off
off
on
off
off
off
off
pp72x48pn9
1. PP module
off
off
off
on
off
off
off
off
pp72x48pn8
2. PP module
on
on
on
off
off
off
off
off
pp72x48pn7
3. PP module
off
on
on
off
off
off
off
off
pp72x48pn6
4. PP module
on
off
on
off
off
off
off
off
pp72x48pn5
5. PP module
The device name consists of the PROFINET name and the device number: in the case of I/O modules,
the 1st module is device number 9.
Note
A newly set PROFINET address will only come into effect after power OFF/ON.
The switch positions 9 and 10 guarantee the PROFINET functionality of the module and must
always be switched "on".
7.7.3.3
X111, X222 and X333 pin assignment
Pin assignment
Table 7-88
Pin assignment X111
Pin
Signal name
Type
Pin
Signal name
Type
1
M
GND
2
P24OUT
VO
3
DI 0.0
I
4
DI 0.1
I
5
DI 0.2
I
6
DI 0.3
I
7
DI 0.4
I
8
DI 0.5
I
9
DI 0.6
I
10
DI 0.7
I
11
DI 1.0
I
12
DI 1.1
I
13
DI 1.2
I
14
DI 1.3
I
15
DI 1.4
I
16
DI 1.5
I
17
DI 1.6
I
18
DI 1.7
I
19
DI 2.0
I
20
DI 2.1
I
Connectable components
7.7 PP 72/48D 2/2A PN
PPU
194
Manual, 01/2014, 6FC5397-2DP40-3BA3
Содержание SINUMERIK 828D PPU Series
Страница 12: ......
Страница 34: ......
Страница 42: ......
Страница 52: ......
Страница 92: ......
Страница 150: ... r r r Connectable components 7 4 Electronic handwheel PPU 150 Manual 01 2014 6FC5397 2DP40 3BA3 ...
Страница 224: ......
Страница 226: ......
Страница 240: ......
Страница 244: ......