LED displays on the rear
For diagnostic purposes, the RJ45 sockets are each equipped with a green and a yellow LED.
This allows the following information on the respective port to be displayed:
Name
Color
Status
Meaning
Link
Green
Lit
100 Mbit link available
Off
Missing or faulty link
Activity
Yellow
Lit
Sending or receiving
Off
No activity
Next to the PN1 port there are two status LEDs (Fault, Sync) that apply to both ports:
Name
Color
Status
Meaning
Fault
Red
Off
For the 828D, all possible I/O modules, machine
control panels and PN/PN couplers are
connected. This is the reason why this status is
not relevant for diagnostics.
Red
Bus fault:
● No physical connection to a subnet/switch
● Incorrect transmission rate
● Full duplex transmission is not activated
Flashing red (2 Hz)
For the 828D, this is a normal state and does not
represent incorrect behavior.
Sync
Green
Off
The SINUMERIK 828D task system is not
synchronized to the send cycle of PLC I/O
Interface. An internal substitute clock of the same
size as the send clock is generated.
Green
The SINUMERIK 828D task system has been
synchronized to the cycle for PLC I/O Interface,
and data exchange is running.
Flashing green (0.5 Hz)
The SINUMERIK 828D task system has been
synchronized to the cycle for PLC I/O Interface,
and cyclic data exchange is running.
LED displays on the front
The three LEDs located behind the front flap at the front of the PPU have the following
significance:
Name
Color
Status
Meaning
RDY
Green
Lights up
NC Ready and PLC in run mode.
Yellow
Lights up
PLC in stop mode
Flashing
Power-up
Interface description
6.4 PLC I/O Interface based on PROFINET
PPU
74
Manual, 01/2014, 6FC5397-2DP40-3BA3