Number
of axes
Port 1 at the PPU
X100
Port 2 at the PPU
X101
Port 3 at the PPU
X102
Example in the figure:
8
1 x LM
4 x MoMo
1 x SMy at the 4th MoMo
1 x TM54F
1x MoMo
1 x Hub DMx
4 x SMy at the Hub DMx
1 x NX10.3
1 x TM54F
3 x MoMo
1 x SMy at NX10.3
1 x SMy at TM54F
1 x SMy at the 3rd MoMo
8
1 x LM
4 x MoMo
1 x SMy at the 4th MoMo
1 x TM54F
2x MoMo
1 x Hub DMx
5 x SMy at the Hub DMx
1 x NX10.3
1 x TM54F
2 x MoMo
1 x SMy at NX10.3
1 x SMy at the 2nd MoMo
SINAMICS S120 Combi
3
3x Combi
1xSMy at the Combi
not used
1 x TM54F
1 x Hub DMx
2 x SMy at the Hub DMx
---
4
3x Combi
1xSMy at the Combi
1 x booksize compact
1 x TM54F
1 x Hub DMx
3 x SMy at the Hub DMx
---
4
4x Combi
1xSMy at the Combi
not used
1 x TM54F
1 x Hub DMx
3 x SMy at the Hub DMx
---
5
4x Combi
1xSMy at the Combi
1 x booksize compact
1 x TM54F
1 x Hub DMx
4 x SMy at the Hub DMx
---
6
4x Combi
1xSMy at the Combi
2 x booksize compact
1 x TM54F
1 x Hub DMx
5 x SMy at the Hub DMx
---
5.4
Topology example without Safety Integrated functions
Note
These wiring examples are valid using the standard clock cycle setting and do not take into
account any Safety Integrated functions.
For further notes on Safety Integrated functions, see the
SINAMICS S120 Safety Integrated Function Manual.
Rules for permitted topologies
5.4 Topology example without Safety Integrated functions
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
59
Содержание SINUMERIK 828D PPU Series
Страница 12: ......
Страница 34: ......
Страница 42: ......
Страница 52: ......
Страница 92: ......
Страница 150: ... r r r Connectable components 7 4 Electronic handwheel PPU 150 Manual 01 2014 6FC5397 2DP40 3BA3 ...
Страница 224: ......
Страница 226: ......
Страница 240: ......
Страница 244: ......