Table 7-52
Technical data of the outputs of X111 to X114
Parameter
Value
Voltage:
0 V to 5 V (depending on the load)
Typical load current (without external
series resistor):
8 mA at LED flow voltage = 2.3 V
15 mA at short-circuit
Switch S1, S2
2))
6
6
21
Table 7-53
Setting of switch S1 as delivered
1
2
3
4
5
6
7
8
9
10
Meaning
ON
ON PLC I/O Interface
OFF OFF OFF OFF OFF OFF OFF OFF
PROFINET address "0"
The two switches S1-9 and S1-10 must remain set to "ON".
The switches S1-1 to S1-8 define the PROFINET address. For a SINUMERIK 828D, the address "64"
must always be assigned to the MCP.
Table 7-54
Switch S1 settings
1
2
3
4
5
6
7
8
9
10
Meaning
ON
ON
ON
OFF OFF OFF OFF OFF OFF
OFF
PROFINET address "64"
The handwheel signal type is set with switch S2-1.
Table 7-55
Switch S2 settings
1
Meaning
ON
differential interface
OFF
TTL interface
Note
Switch S2-2 is reserved for test purposes.
Connectable components
7.3 MCP Interface PN
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
145