Note
If a Pt100 element is accidentally not connected in this operating mode and an input voltage
higher than 0.25 V is output, the analog module automatically switches to the "no operating
mode" operating mode and resets the gain factor to "1". This is signalized in Status Word 0
(channel-specific) in the input image. In addition, a corresponding error code is output in the
diagnostics slot at a counter value of "2".
In the case of operation without a Pt100 element, a slightly negative voltage may be applied,
which results in an error status for the module. Here, the "PNFault" LED and the status byte
1 are to be observed.
Analog outputs
Table 7-110 Measured values in the "voltage output" operating mode
16 bit value (hex.)
16 bit value (dec.)
Factor
Voltage value [V]
Overflow
-
Deactivation
Overrange
-
Up to 10.5 V
0x6666
26214
0.000381469
10 V
0x4CD1
19665
7.5 V
0x199B
6555
2.5 V
0x0000
0
0 V
0xE665
-6555
-2.5 V
0xB32F
-19665
-7.5 V
0x999A
-26214
-10 V
Underrange
-
Up to -10.5 V
Underflow
-
Deactivation
Table 7-111 Measured values in the "current output" operating mode
16 bit value (hex.)
16 bit value (dec.)
Factor
Current value [V]
Overflow
-
Deactivation
Overrange
-
20.2 mA
0x6666
26214
0.0007629
20 mA
0x4CD1
19665
15 mA
0x199B
6555
5 mA
0x0000
0
0 mA
0xE665
-6555
-5 mA
0xB32F
-19665
-15 mA
0x999A
-26214
-20 mA
Underrange
-
-20.2 mA
Underflow
-
Deactivation
Connectable components
7.7 PP 72/48D 2/2A PN
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
211