Table 7-114 Measured values and responses in the temperature measurement operating mode
Address
Pt100
Incorrect operating mode
Resistor is not connected
Operating mode
QB72
16#AA
16#0F
Format
QB73
16#1
16#1
Value
QW76
-
-
Value
QW78
-
-
Operating mode
IB72
16#AA
16#0F
Format
IB73
16#81
16#81
Value
IW76
-
-
Value
IW78
-
-
Diagnostics
IB50
16#2
16#2
IB51
16#3
16#6
PNFault LED
on
on
Troubleshooting
Deactivating/activating
Deactivating/activating
7.7.5
Technical data
PP 72/48D 2/2A PN I/O module
Parameter
Value
Input voltage
24 V DC + 20% / - 15%
Power consumption at rated load
(without digital outputs)
19 W
Power loss
18 W
Rated current
0.7 A
Shock load during transportation (in transportation
packaging)
Free-fall ≤ 1 m
Degree of protection in acc. with EN 60529
IP00
Protection class in acc. with EN 61800-5-1
III; DVC A (PELV)
Approvals
CE, cULus
Heat dissipation
Open-circuit ventilation
Condensation
Not permitted
Limits for relative humidity at 25 °C:
● Storage
● Transportation
● Operation
5 ... 95% without condensation
5 ... 95% without condensation
5 ... 90% without condensation
Connectable components
7.7 PP 72/48D 2/2A PN
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
213
Содержание SINUMERIK 828D PPU Series
Страница 12: ......
Страница 34: ......
Страница 42: ......
Страница 52: ......
Страница 92: ......
Страница 150: ... r r r Connectable components 7 4 Electronic handwheel PPU 150 Manual 01 2014 6FC5397 2DP40 3BA3 ...
Страница 224: ......
Страница 226: ......
Страница 240: ......
Страница 244: ......