Name
Function
Status
Meaning
H501
BUS_SYNC
Does not light
up
No PROFINET communication.
Lights up
PROFINET is synchronized (STOP state).
Flashes (0.5
Hz)
PROFINET is synchronized (RUN state).
H502
BUS_FAULT
Lights up
PROFINET group fault.
H505
Temperature alarm (red) Lights up
At least one temperature limit is being exceeded.
7.3.1
Mounting
Installation
The module can be attached at a suitable position via the four mounting holes (e.g. behind the
machine control panel or in the control cabinet). The selection of the appropriate mounting
position depends on the interfaces used and the associated maximum cable lengths.
Four standard torx-slotted screws T20/M4 are used to attach the module.
MCP Interface PN dimension drawing
[
Figure 7-23 MCP Interface PN dimension drawing
Connectable components
7.3 MCP Interface PN
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
133