Function-impairing dust
When working in areas where gases, dust and oils may be hazardous to functionality, the
control system must be operated in an enclosure with a heat exchanger or with suitable supply
air.
Table 3-3
Maximum permissible dust content in the air
Suspended component
0.2 mg/m
3
Deposits
1.5 mg/m
2
h
Note
Dust deposits must be removed at regular intervals.
Radio interference
Applicable standards: EN 61800-3
Table 3-4
Limit values for radio interference suppression in industrial environments
Limit class according to EN 61800-3
Conducted radio interference
C3
Radio interference
C3
Note
The user must consider interference radiation for the complete system. Particular attention
should be paid to cabling. Please contact your sales representative for assistance and
support.
If compliance with limit value class C2 is required, please contact your local Siemens sales
partner.
Note
Please see the relevant SINAMICS documentation for EMC notes on how to deal with line
filters and reactors.
3.3
Recycling and disposal
Products should be disposed of corresponding to the relevant national regulations.
The products described in this manual can be mostly recycled due to the fact that they contain
very few damaging substances. To recycle and dispose of your old device in an
environmentally friendly way, please contact an appropriate disposal company.
Application planning
3.3 Recycling and disposal
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
41