Value
byte 1
Cause
Effect
Remedy
6
Overrange at the inputs
Check input circuit and adjust, if required.
7
Overrange at the outputs
Correct values in the user program.
1)
The analog outputs retain their last specified value.
Diagnostics via Status Bytes 0/1
In Status Byte 0, the set operating modes are reflected e.g. "0x55" if Control Byte 0 = 0x55
has been specified.
In the event of an error, the error bit is set in Status Byte 1 (bit 7). In the event of an error in
one channel, all channels are disabled.
Table 7-79
Input image of analog inputs (excerpt)
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit3
Bit1
Bit0
m+0
0
0
0
0
0
0
0
0
m+1
Error bit
0
0
0
0
0
0
0
7.6.5
Technical data
PP 72/48D PN I/O module
Parameter
Value
Input voltage
24 V DC + 20% / - 15%
Power consumption at rated load
(without digital outputs)
17 W
Degree of protection in acc. with EN 60529
IP00
Protection class in acc. with EN 61800-5-1
III; DVC A (PELV)
Shock load during transportation (in transportation
packaging)
Free-fall ≤ 1 m
Approvals
CE, cULus
Cooling
Open-circuit ventilation
Condensation
Not permitted
Limits for relative humidity at 25 °C:
● Storage
● Transportation
● Operation
5 ... 95% without condensation
5 ... 95% without condensation
5 ... 90% without condensation
Temperature limits:
● Storage
● Transportation
● Operation
-40 ... 70 °C
-40 ... 70 ℃
0 ... 55 °C
Connectable components
7.6 PP 72/48D PN
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
183