Analog inputs
Table 7-107 Measured values in the voltage measurement operating mode
16 bit value (hex.)
16 bit value (dec.)
Factor
Voltage value [V]
Overflow
-
Deactivation
Overrange
-
Up to 11.75 V
0x19B5
6581
0.00151947
10 V
0x0CDA
3291
5 V
0x066D
1645
2.5 V
0x0000
0
0 V
0xF993
-1645
-2.5 V
0xF326
-3291
-5 V
0xE64B
-6581
-10 V
Underrange
-
Up to -11.75 V
Underflow
-
Deactivation
Table 7-108 Measured values in the current measurement operating mode
16 bit value (hex.)
16 bit value (dec.)
Factor
Current value [V]
Overflow
-
Deactivation
Overrange
-
Up to 23.5 mA
0x1999
6553
0.003051758
20 mA
0x0CCC
3277
10 mA
0x0000
0
0 mA
0xF333
-3277
-10 mA
0xE666
-6553
-20 mA
Underrange
-
Up to -23.5 mA
Underflow
-
Deactivation
Table 7-109 Measured values in the "temperature measurement" operating mode
16 bit value (hex.)
16 bit value (dec.)
Factor
Temperature value [V]
Overflow
0x0A28
2590
0.1
259 ℃
0x03E8
1000
100 °C
0x01F4
500
50 ℃
0x0000
0.0
0 °C
0xFE0C
-500
-50 ℃
0xFC18
-1000
-100 °C
0xF830
-2000
-200 ℃
Underflow
Connectable components
7.7 PP 72/48D 2/2A PN
PPU
210
Manual, 01/2014, 6FC5397-2DP40-3BA3
Содержание SINUMERIK 828D PPU Series
Страница 12: ......
Страница 34: ......
Страница 42: ......
Страница 52: ......
Страница 92: ......
Страница 150: ... r r r Connectable components 7 4 Electronic handwheel PPU 150 Manual 01 2014 6FC5397 2DP40 3BA3 ...
Страница 224: ......
Страница 226: ......
Страница 240: ......
Страница 244: ......