Optional customer buttons OUT (X53 / X54)
The short-circuit-proof outputs X53/X54 are provided to control lamps in the buttons. Lamps
with 24 V and 1.2 W per output are recommended.
;
0
0
3
.7287
.7287
.7287
;
0
0
3
.7287
.7287
.7287
Figure 7-7
Main circuit diagram for input circuit for X53 and X54
CAUTION
Do not connect any relays, valves or other inductive loads.
Connector designation: X53, X54
Connector type: 4-pin plug connector
Table 7-6
Assignment of connector X53
Pin
Signal name
Signal type
Meaning
1
KT-OUT1
O
Output 1 lamp
2
KT- OUT2
Output 2 lamp
3
KT- OUT3
Output 3 lamp
4
M
V
Ground
Table 7-7
Assignment of connector X54
Pin
Signal name
Signal type
Meaning
1
KT-OUT4
O
Output 4 lamp
2
KT- OUT5
Output 5 lamp
3
KT- OUT6
Output 6 lamp
4
M
V
Ground
Connectable components
7.1 MCP 483C PN
PPU
102
Manual, 01/2014, 6FC5397-2DP40-3BA3
Содержание SINUMERIK 828D PPU Series
Страница 12: ......
Страница 34: ......
Страница 42: ......
Страница 52: ......
Страница 92: ......
Страница 150: ... r r r Connectable components 7 4 Electronic handwheel PPU 150 Manual 01 2014 6FC5397 2DP40 3BA3 ...
Страница 224: ......
Страница 226: ......
Страница 240: ......
Страница 244: ......