Use
DRIVE-CLiQ interfaces are used to connect SINAMICS S120 components to the PPU.
The following rules apply:
● Topology rules for S120 Combi (Page 53)
● Topology rules for S120 Booksize (Page 54)
● Topology rules for Safety Integrated functions (Page 58)
● Topology example without Safety Integrated functions (Page 59)
● Topology example with Safety Integrated functions (Page 63)
DRIVE-CLiQ has the following properties:
● Components can be independently expanded
● Automatic detection of components by the PPU
● Standardized interfaces to all components
● Uniform diagnostics down to the components
● Complete service down to the components
Cable specification for X100 - X102
Feature
Version
Connector type
RJ45 socket with 180° cable outlet
Cable type
MOTION-CONNECT
Article number
6FX2002-1DC00-1□□0
Max. cable length
70 m
Blanking cover for DRIVE-CLiQ interface: Tyco company, article number: 969556-5
Note
Interfaces X100 to X102
The interfaces X100 to X102 of the PPU do not provide any 24 V supply voltage.
Consequently, no components, such as SME, can be connected here that must be supplied
with 24 V via DRIVE-CLiQ.
Additional references
Further information on the components in this section:
● SINAMICS S120 Control Units and Additional System Components Manual
● SINAMICS S120 Booksize Power Units Manual
● SINAMICS S120 Booksize Power Units with Cold Plate Manual
● SINAMICS S120 Combi Manual
Interface description
6.6 DRIVE-CLiQ
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
85