LEDs
Color
Status
Description
Flashing 2 Hz
Writing to CompactFlash card
Red
Continuous light
NX10.3 is presently booting and at least one fault is pending (e.g.
RESET, watchdog monitoring, basic system fault).
Flashing 0.5 Hz
Boot error (e.g. firmware cannot be loaded into the RAM)
Yellow
Continuous light
Firmware is being loaded into the RAM.
Flashing 0.5 Hz
Firmware cannot be loaded into the RAM.
Flashing 2 Hz
Firmware CRC fault
DP
Off
Electronics power supply outside permissible tolerance range:
NX10.3 is not ready for operation.
Green
Continuous light
CU_LINK is ready for communication and cyclic communication is
running.
Flashing 0.5 Hz
CU_LINK is ready for communication and cyclic communication is not
running.
Red
Continuous light
At least one CU_LINK fault is present.
CU_LINK is not ready for operation (e.g. after switching on).
RESET button
The RESET button is on the front of the module under the cover.
Note
When the pushbutton is actuated, the locally connected drive systems are brought to a
standstill with no feedback to the control. In other words, the drive and control run
asynchronously once the drive has been successfully powered up.
7.8.2
Mounting
Designs
The NX10.3 is integrated into the SINAMICS drive line-up. For the preferred installation
sequence, the NX module should be mounted at the side of the Line Module.
NOTICE
Protection against overheating
The 80 mm ventilation spaces above and below the components must be observed.
Connectable components
7.8 NX10.3
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
217